To put it plainly there isn t a safe distance.
Fall protection distance from roof edge.
Unprotected sides and edges.
Between 6 feet and 15 feet from the edge.
Related regulations add to my handbook.
6 is the minimum distance from the edge of the roof or from a hole in the roof at which you must erect a warning line during roofing work if a warning line is your fall protection of choice.
G11 1 definitions anchor and anchorage g11 2 1 calculation of fall distance when on a sloped roof g11 2 2 selecting a method of fall protection g11 2 3 defining a fall restraint versus fall arrest system g11 2 4 tilt up construction g11 2 5 fall protection in agriculture g11 2 5 1 safety monitor system as a work procedure.
Minimum edge distance for roofing work.
Is there a safe distance from the edge of a roof for construction workers doing work while on a roof but not engaged in roofing residential pre cast erection or leading edge work.
Usm permanent guardrail the usm guardrail system provides permanent full perimeter fall protection.
Each employee on a.
For general industry working at a 4 foot height or a low sloped roof osha requires.
Between 6 feet and 15.
Section 1926 501 b 10 sets out the fall protection requirement for roofing work on low slope roofs.
In principal i agree with those who say that as you increase the distance to an unprotected edge you decrease the probability of a fall.
Without fall protection from unprotected edge 50 ft minimum.
Never exceeds 6 ft.
The unique design allows 100 water tight installation under standard roofing and sheet metal details including coping caps drip edges gravel stops and even inside most commercial gutters without penetrating the roof membrane.
Employers are to ensure that each employee is protected from falling by using fall protection systems such as guardrails safety net system fall restraint or fall arrest systems.
Answer background in 29 cfr part 1926 subpart m fall protection 1926 501 b 1 states.
Low slope roofing work only roof 50 ft requires warning line at 6 ft monitor to edge.
Less than 6 feet from the roof edge.
6 feet from the edge.
Safe distance to an unprotected roof edge is a common area of misunderstanding when discussing fall protection.
Under that section an employer may use a combination of warning lines 6 feet and in some cases 10 feet back from the edge in combination with monitors in place of personal fall protection equipment or guardrails.
Conventional fall protection guardrail fall restraint or fall arrest system is required.