Its appearance can complement any style of building from the traditional to the.
Flat seam copper roof details.
The locking strip is turned out 45 degrees a minimum of 3 4.
These pans run parallel to the slope of the roof and are joined to adjacent pans with double locked standing seams.
The edge strip shown in detail 1 is attached to the fascia board with nails at 3 o c.
Horizontal flat lock systems.
These divisions are comprised of one or more drawings each with a facing page of descriptive text.
Pac 150 180 double lock.
Coil and flat sheet.
Racking of cleats due to cyclical expansion contraction.
Architectural metal roofing panels metal wall panels and related products such as soffit panels highest quality fascia and coping systems.
Download cad file download cad file.
The horizontal flange in detail 2 projects back onto the roof a maximum of 4.
Copper materials are shown in copper color all other building materials are shown in black.
Standing seam roofing is composed of preformed or field formed pans usually between 14 to 18 inches wide when finished.
This 120 page technical manual copper roofing in detail aims to provide architects and contractors with the technical information needed to design and install fully supported sheet copper roofing in accordance with current good practice.
Flat seam roofs used in low no slope areas or areas subject to flooding or standing water typically made from 20 x 28 sheets relative geometry is important fro expansion and contraction sheet use efficiency and wind load.
Structural strength of the formed pans.
The details illustrated will meet most of the conditions likely to be encountered.
Flat seam roofing systems are typically used on roofs that are flat or have a low pitch or alternatively on very steep slopes.
Potential problems with standing seam roofs due to expansion and contraction stem from three conditions.
It is secured with copper or copper alloy nails spaced 3 apart.
This type of wall panel is basically identical to flat seam roofing applied on a vertical surface.
Pac 150 90 single lock.
Rectangular cold rolled copper sheets.
Copper or stainless steel is recommended lock and seal all joints solder joints on slopes less than 3 12.
The recommended dimensions should be specified from the table below.
However neither solder nor sealant is required in the joints since the vertical surface provides positive drainage.
The drawings are presented in two colors.
Flat seam roofing is constructed of 18 by 24 20 oz.
For example in the roofing systems there are divisions for standing seam batten seam flat seam roofing and more.